Welcome

There's much to see here. So, take your time, look around, and learn all there is to know about us. We hope you enjoy our site and take a moment to drop us a line.

Menu / Price List

Add a footnote if this applies to your business

What We Service

Pumps

Single speed, 2-speed, VSP, VSF, and SVRS

Filters

Cartridge, sand, and D.E., including sand changes and media upgrades 

Heaters

Sanitizer Systems

Raypak/Rheem, Pentair, Hayward, Jandy, Sta-Rite, Coates, in natural gas, propane, & electric

Sanitizer Systems

Sanitizer Systems

In/off-line erosion feeders, cal hypo feeders, liquid chlorine, hydrogen peroxide, ion systems, UV, salt chlorine   generators, & biguanide

Salt Systems

Salt Systems

Pentair, Hayward, Jandy, & AutoPilot

Automation

Salt Systems

Pentair EasyTouch, IntelliTouch, IntelliCenter, IntelliChem, Levelor autofill; Jandy RS and AquaLink; Hayward OmniHub and AK110; Polaris 

Plumbing

Schedule 40 PVC hard pipe, Schedule 80 where appropriate. We do not use flex PVC or hollow-core drain pipe and fittings 

Gas & Electrical

 Gas lines and connections, electrical work for pool equipment 

& More

& More

Skimmer Replacement, Light Repair & Replacement Including Bulb, LED Panel & Fixture.

Pumps

Single Speed Pumps

Variable speed/Variable Flow pump

Single Speed Pumps

Single speed pumps are the most common pumps found on pools until recently. They are usually in 115v/230v single phase configurations, although can also be found in 208/230 configurations as well as 3 phase options on larger pumps. These pumps operate at 1 speed, and are either ON or OFF. The majority of these pumps (more specifically the motors) will no longer be produced as of July of 2021. The main exception is the 1HP Hayward Super Pump. This is the only relevant single speed pump to meet the new energy efficiency requirements. All other single speed pumps such as the whisperflo, superflo, stealth, utilitec, etc. will need to be replaced by an appropriate VSF pump, once the current single speed motor is no longer operable. 

2 Speed Pumps

Variable speed/Variable Flow pump

Single Speed Pumps

2 Speed pumps are most frequently seen used in hot tubs. They are wired for a low speed and high speed mode. The low speed is designed for basic circulation/filtration purposes, as well as running the heater,  while the high speed mode is to provide powerful jets when the hot tub is in use. These pumps will also require replacement with VSP/VSF pumps after July 2021 as per the US Dept. of Energy. VSP/VSF pumps offer greater control, as you can set the specific speeds/flow rates for the pump to operate at and does so with a much higher level of energy efficiency. 

Variable speed/Variable Flow pump

Variable speed/Variable Flow pump

Variable speed/Variable Flow pump

Variable Speed/Variable Flo pumps are the way of the future with pool pumps. They offer an incredible amount of versatility, energy efficiency and features. There are built in timers, giving you unprecedented control, and allowing you to run your pump at a higher speed during peak sunlight hours, and slow it down to conserve energy at night, while still continuing to filter, circulate, sanitize and heat when there is no need to run it at high speed. They are also very versatile in terms of deck sprayers, fountains, waterfalls, etc, and being able to program the pump for the correct adjusted flow as each water feature demands additional water. For commercial applications there are also SVRS models, which incorporate a self resetting vacuum release which is Virgina Baker Act compliant, to avoid the possibility of entrapment. 

Filters

Sand Filters

Cartridge Filters

Beige water filter tank with black base and top.

Sand filters are the best option for all around performance. With typical pool sand, it should be changed every 3-5 years. Typical size filters for spas and pools are 300lb and 600lb filters. Sand will begin to "round out" the edges, and become eroded, which help trap debris making it less effective. If sand is left unchanged for longer periods, it will literally begin to for sedimentary rock, as the water compacts and erodes the sand into more solid chunks, with channels flowing though at the points of least resistance. This allows the water to push through the filter, without removing any debris and is referred to as "channeling." Sand filters with standard pool sand are generally rated to filter down to 20-40 microns in size. However, sand is not the only media available for filtering! Activate glass media is an alternative that looks like sand to the naked eye, but provides even finer filtration at 5-10 microns in size. That's even finer than cartridge filters are capable removing! It would still require replacement every 3-5 years. With the addition of the multiport valve, it provides a recirculation option for bypassing the filter, and still being able to circulate water, allowing for chlorination, heating and surface skimming, in the event there is an issue with the filter. It also provides a winterization option, closed position, backwash AND rinse (unlike "push/pull" valve). Sand filters offer a quality, reliable means of filtration with  that is easily upgradeable with media at ANY sand change without any costly equipment changes

Cartridge Filters

Cartridge Filters

White industrial filtration tank with gauges and valves.

Cartridge Filters were really designed as a less maintenance version of a D.E. filter. They offer better filtration over standard pool sand in a sand filter. Generally cartridge filters are able to filter particles anywhere from about 5-20 microns in size. Cartridges are removable and cleanable for a finite period. The best way to clean cartridge filters are to pressure wash them, with a wide nozzle. There are chemical cleaners,  available as well. Most recommended would be a "soak style" cleaning agent that would be added to water, and allow the cartridges to soak in the solution for the recommended period of time, remove and pressure wash thoroughly to remove any additional solvents or detergents, and then replace. Cartridge life is not as long as sand or glass. Generally we would recommend having 2 sets of cartridges for each cartridge filter. When the active set is dirty, they can be removed and cleaned, and the alternate set can go into the filter, so the system is never down. The alternating cartridges also extend the life of both sets. At the end of each season,  evaluate both sets and if a set needs replacement.... whichever set is worse, should be replaced with a new set. Use the worse looking filters for any algae cleanups, openings, etc. The cost on cartridges (depending on the specific model, design and number of cartridges) range  on average between $100-$800.

Diatamcious Earth Filters(d.e)

Diatamcious Earth Filters(d.e)

Vertical swimming pool sand filter with valve.

D.E. or Diatomaceous Earth filters have the highest level of filtration available, able to filter out particulate from 1-6 microns in size! However the increased filtration comes at a cost. D.E. filters work by flowing water through a set of concentric screens inside the filter. The screens themselves are not what filter the water. The screens are what "catch" and hold the D.E. Once the screens are coated in D.E. the water is filtered through that coating. D.E. (like sand) will need to be cleaned out periodically. This is done with either a multiport valve like the sand filter and backwashing by flushing water "backwards" through the screens and then out a waste line, or by "bumping" the filter and backwashing depending on the style of D.E. filter. After the backwash is done, new D.E. needs to be added again, in order for the filter to be functioning again. To do this....Fresh D.E. must be added with the system running, through the skimmer, 1 cup at a time. D.E. is made from the fossilized remains of tiny, aquatic organisms called diatoms. Their skeletons are made of a natural substance called silica. Over a long period of time, diatoms accumulated in the sediment of rivers, streams, lakes, and oceans. Today, silica deposits are mined from these areas. Silica is also a known carcinogen when inhaled, and caution should be taken when handling. Additionally the screens inside must be removed and cleaned thoroughly to remove deposits of old d.e as well as debris.  

Heaters

Raypak 206/266/336/406

Raypak 206/266/336/406

Raypak 206/266/336/406

Black and gray electronic device with a display.

Raypak heaters are the leading name in pool heaters for a variety of reasons, and the ONLY heaters 4074 Pools and Spas recommends to our clients. They are estimated to hold around 40% of the total market share of installed pool heaters. Raypak is a heater company! Not a pool company making a heater. Raypak heaters use cutting edge technology that produces a great product that is safe, efficient, and reliable! Raypak's digital heaters have an on demand ignition. When there is a call for heat, safety sensors are checked, an electric ignition ignites the pilot. Once the system acknowledges the lit pilot it opens the main gas valve for full burner ignition. There is no HSI or element to burn out over time, reducing maintenance cost. Additionally Raypak is now using cupro-nickle heat exchangers in all of their heaters instead of copper heat exchangers which are more durable and necessary for high corrosive environments like saltwater pools. Additionally, they now include a sacrificial metal anode on the header which offers a water bond, which provides further protection of the heat exchanger. Because there is not a sealed combustion chamber like competitors models (mastertemp, jxi, Sta rite max E Therm), the sulfuric acid created through the burning of natural gas, mixed with the condensation of exhaust gas, never drips down and gets captured on the heat exchanger, doing significant damage, and shortening the life of the heater. It is able to drip through to the burn pan and give the heater a long lasting reliable heater, with less long term maintenance costs. They have "high wind stacks" for applications that produce a high wind issue causing down draft and rollout issues in the heater. Additionally for indoor installations, they can be paired with the D-2 Power Ventilator which forces the exhaust gases out of the flue pipe quickly, making these incredibly versatile units as well! This reduces the chance of condensation forming, as the hot exhaust gases travel along the cooler duct pipe, causing condensation to drip through the sulfur dioxide in the exhaust, causing sulfuric acid to damage the heat exchanger. They are available in natural gas OR propane models. High altitude models are all we use in Denver and surrounding areas. Compatible with all automation controllers. ASME models available for commercial use as well as X94 models for high efficiency heating requirements.

Pentair Master Temp

Raypak 206/266/336/406

Raypak 206/266/336/406

A vintage slide projector.

Pentair Mastertemp heaters hold 2nd place with around 25% of the market share. They have become a very popular option in the industry. Pentair is a big name in the industry. This heater design was to provide a different option than the Raypak. Instead of the atmospheric design of the Raypak, the Pentair Mastertemp uses a sealed combustion chamber, and a gas fed blower design for the flame. They use a copper heat exchanger, as opposed to the upgraded cupro-nickel in the Raypak making them more susceptible to corrosion and electrolysis. They are not as flexible with gas input adjustments. The Raypak gas valves are adjustable for a higher or lower line pressure. This can not be adjusted with the Mastertemp series style heaters. The reason is because the combustion requires a specific air/fuel mix for proper combustion. The adjustment of the gas valve in that style system, would cause the flame to become "rich" (too much fuel) or "lean" (more air than fuel) which can damage the heater. Pentair heaters work great when paired with Pentair automation systems, but not well with 3rd party units, such as hayward omni logic. 

Jandy JXi

Raypak 206/266/336/406

Hayward H Series

Compact gray and black industrial or laboratory device with vent and control knobs.

The Jandy JXI is responsible for about another 15% of market share. The ironic part is, that the JXI is widely considered to be like the Pentair Mastertemp 2.0. It's a little bit smaller, a little bit lighter, has an adjustable manifold that can be easily moved depending on the specific pad spacing and availability. The exhaust manifold can also be moved as well for the same reason. It also has a "versa flo" manifold which can help to automatically control bypass flow through the heater's own header, which helps with flexibility of variable speed pumps. However the JXI still uses the same sort of hot surface ignitor to light, same blower system for combustion as the master temp.  They both still utilize the plastic housing for weight reasons. 

Hayward H Series

Sta Rite Max e therm

Hayward H Series

Industrial paper shredder machine.

Hayward H series heaters are responsible for about 15% of heaters. They are closer to the Pentair Mastertemp, Jandy JXI, or Sta-Rite/Max E Therm heaters than the Raypak as well. It ALSO features a blower style forced induction styled burner setup. The shape and layout is unique to Hayward, however it functions in the same way as a Mastertemp/Jxi. The main advantage with the Hayward is, like Raypak, they have upgraded their internals from a copper heat exchanger to a cupro-nickel exchanger that is more durable. Additionally the heater cabinet is made of a galvanized sheet steel, much more like the Raypak than the Pentair or jandy versions. This makes the heater a bit heavier, but a bit more robust as well. It's ease of accessibility is probably one of the more difficult to access and its plumbing layout doesn't match that of the Pentair, Jandy OR Raypak!

Sta Rite Max e therm

Sta Rite Max e therm

Sta Rite Max e therm

Black pool filter pump with valve attachments.

Sta Rite has been bought out by Pentair, so this is technically now a pentair heater. It is a different shaped housing, however it functions just like a Pentair Mastertemp heater. It has the same forced blower design. The plumbing is in the same place/configuration as the Pentair Mastertemp as well as the Jandy Jxi. 

Hi effiency Heaters

Sta Rite Max e therm

Sta Rite Max e therm

Pool Boilers

Pool Boilers

Pool Boilers

Heat Pump

Pool Boilers

Pool Boilers

Sanitation Systems

Aquarium protein skimmer with accessories.

In Line Erosion System (chlorine/Bromine)

Weather station sensor with cables and mounting accessories.

Off line Erosion Systems (Chlorine/Bromine)

Industrial electrical connector.

Salt Water Chlorine Generators

Blue and white Pulsar air purifier.

Calcium Hypochlorite (Form of chlorine)

Blue chemical drum labeled sodium hydroxide.

Liquid Chlorine

Hydrogen Peroxide

Biguanide (commonly known as baquacil)

Ultra Violet Sterilization

Ion System

Automation

Various smart home devices including thermostat and control panels.

Pentair Intellicenter

Pentair Intellichem

Electronic water fill system by Levelor.

Levelor AutOmatic Water FILL